Add to Favorites
Share

MMO titanium ribbon anodes used in storage tank for cathodic protection system

  • Description
Product Detail

    MMO titanium ribbon anodes used in storage tank for cathodic protection system

    Equipped with professional factory, Taijin Industrial is the biggest China manufacturer, supplier and producer of mmo ribbon anode. Our company can offer you corrpro vendor cathodic protection system for storage tank, titanium ribbon, titanium anodes, titanium electrodes, mmo ribbon at competitive price.


                                                                                TAIJIN RIBBON ANODE FOR

                                                         CATHODIC PROTECTION of GROUND STORAGE TANKS

    TAIJIN Mixed Metal Oxide (MMO) Ribbon Anodes have an excellent Electrocatalytic property. The evolution of Oxygen & Chlorine and / or mixtures of the two Gases can be established with a Low Stable Anode Potential.

    TAIJIN Mixed Metal Oxide Ribbon Anodes are used for various applications including use in above ground storage tank base plates.

    TAIJIN MMO Ribbon Anode-we passed the test of the third party- Det Norske Veritas (U.S.A.), Inc. Under the standard of MMO Ribbon-NACE TM0108.

    1.Substrate

    Titanium ASTM B 265  Grade I / II

    2.Coating : IrO2/Ta2O5


    3.Specification
    1)Other specification can be available as client's requirement.

    General Dimensions of Ribbon (Fine Sand)

    width

    (mm)

    Coil length

    (m)

    thickness

    (mm)

    Current Rating

    surface area of ribbon

    (m2/m)

    Coil Weight (kg)

    Lifespan

    (years)

    6.35

    76.2 / 152.4

    0.635

    17ma/m

    0.014

    2.8

    50

    6.35

    76.2 / 152.4

    0.635

    42ma/m

    0.014

    2.8

    50

    Titanium Conductor Bar Dimensions

    width

    (mm)

    Coil length

    (m)

    thickness

    (mm)

    Coil Weight (kg)

    12.7

    76.2 / 152.4

    0.9

    7.8

    6.35

    76.2 / 152.4

    0.635

    2.8

    4.Accelerated Life


    1mol/L Na2SO4, current density 15000A/m2,

    Test standard: NACE TM0108-2008

    Test Result: 192 hours    


    ??2.png


    5. Our workshop

    Workshop1.jpg


    workshop2.jpg


    5.Advantage
    •Long life;
    •Uniform coating ;
    •Strong binding capacity ;
    •Good stability ;
    •Low consumption rate ;
    •Easy installation, Easy transportation.